Grid Getter Blog

Ireland's Smart Tariffs and Your Powerwall: A Working Guide

Night boosts, EV plans, export payments and storm season. What a stored unit really costs on each Irish smart tariff, and one rule set for the whole year.

Published November 18, 2026 · 9 min read

Ireland finished most of its smart meter rollout, and then the tariff sheet exploded. There are standard smart plans, night boosts, EV plans, free-Saturday plans, and since June 2026 half-hourly dynamic pricing. A Powerwall can make money out of nearly all of them, but Tesla's app only gives you two modes: Self-Powered and Time-Based Control. Time-Based Control with your tariff typed in will charge at night, but Tesla decides how full to get, and nothing changes your reserve from season to season. Irish tariffs reward rules tied to a time window and a season.

Here's how to build those rules for an Irish smart tariff. Rates below are what suppliers and comparison sites showed in mid-November 2026, including VAT unless noted. They move often and the comparison sites disagree with each other, so treat every number as a placeholder for the one on your own bill.

The smart tariff menu, decoded

Almost every plan is a variation on one of four shapes.

  • Standard smart tariff. Three bands: day (8am–11pm), night (11pm–8am) and peak (5pm–7pm). Unlike the old day/night meter plans, the bands don't shift by an hour in summer. On most of its plans Bord Gáis Energy applies peak on weekdays only, so check what your own supplier does.
  • Night boost. Day and night bands plus a short, very cheap window. Electric Ireland's Home Electric+ Night Boost runs 2am–4am. Since the July 2026 price rise it's about 11.5c/kWh on the standard rate, or about 10.9c with the current 5.5% discount. Electric Ireland lists it without a separate peak band.
  • EV plans. A longer cheap window and usually a dearer day rate. Energia's EV Smart Drive runs 2am–6am, Bord Gáis Energy's EV Smart Electricity runs 2am–5am, and SSE Airtricity's Smart EV Max runs 11pm–5am. None of them asks for proof that you own a car, and Bord Gáis says outright you don't need one.
  • Dynamic. The five suppliers with more than 200,000 electricity customers (Electric Ireland, Bord Gáis Energy, Energia, SSE Airtricity and PrepayPower/Yuno) have had to offer a dynamic price tariff since June 2026. You get 48 half-hourly prices for the next day, published the afternoon before. The CRU requires a cap of around 50c/kWh, but there's no floor, so a windy night can go negative.

For a battery, three numbers matter: the cheapest rate, how many hours it lasts, and the gap to your peak rate. The headline discount and the welcome credit matter much less.

Dynamic tariffs are their own subject, covered in our guide to dynamic electricity pricing with a battery. The rest of this post assumes fixed bands, which is still where most Irish Powerwall owners sit.

Night-rate Powerwall charging in Ireland, done properly

Night rate battery charging looks simple: fill up cheap, run the house on it at 5pm. Two details decide whether it pays.

Efficiency sets your real price

A Powerwall gives back about 90% of what you put in. So divide the rate you pay by 0.9 to get what a stored unit really costs:

  • An 11c boost unit costs about 12.2c by the time you use it
  • An 18c ordinary night unit costs about 20c

11c is close to Electric Ireland's discounted boost rate. If yours is lower, every figure below gets better.

Against a day rate in the mid-30s, and a peak rate around 40c if your plan has one, both are worth doing. The boost unit is worth much more.

The window may be shorter than your battery

A Powerwall holds 13.5 kWh. Taking it from a 20% reserve to full means storing 10.8 kWh, which takes about 12 kWh of import.

Powerwall 2 and Powerwall 3 both charge from the grid at up to 5 kW, so that's 2.4 hours. A two-hour boost window gets you 10 kWh of import, about 9 kWh stored. Some installs are configured to charge slower, and every kilowatt below 5 costs you about 1.8 kWh of stored energy in a two-hour window.

You can let charging run past 4am into the ordinary night rate, or accept a part-fill. Running over is usually right in winter. Using round numbers and a 20% floor, 10 kWh at 11c plus 2 kWh at 18c is €1.46. That buys 10.8 kWh you'd otherwise import at around 35c, or €3.78. You come out about €2.30 ahead per night, on nights you'd use the full battery. With the 30–40% winter floor suggested further down, less of the battery cycles and the figure is closer to €1.85–€2.10.

In July you won't use it all, which is where export comes in.

Export payments: worth chasing or not?

Under the Clean Export Guarantee, every supplier pays for what you export, and the rates sit in a fairly narrow band. Electric Ireland and SSE Airtricity pay 19.5c/kWh. Pinergy lists 18.5c before VAT, and PrepayPower is at the bottom at about 15.9c.

Now compare that with your night rate.

Storing a unit of your own solar means not exporting it. At 19.5c and 90% efficiency, solar in the battery costs you 21.7c per unit delivered. A boost unit costs 12.2c. So on a boost or EV tariff, it pays to fill the battery at night even in summer and let the solar go to the grid: about 9.5c per kWh, or 95c on a 10 kWh day. You'll keep less than that in practice. In Self-Powered mode the battery refills from solar whatever it gave the house that morning, and those units don't get exported.

On a plain 18c night rate the same trick earns 1.7c per kWh. Don't bother.

Two limits apply.

  1. The first €400 of export income a year is tax-free, and Finance Act 2025 extended that through 2028. At 19.5c that's about 2,050 kWh. A decent-sized array can get there on ordinary surplus, and anything above it is declarable income.
  2. Discharging the battery to the grid at 5pm looks profitable on paper: about 7c a unit, 19.5c out against 12.2c in. But every unit you export is one you don't use yourself at 35–40c, and covering your own evening use is worth far more.

Export pays when it falls out of a good night-charging rule. It rarely pays as a strategy of its own.

Storm season and the reserve rule

Storm Éowyn cut power to about 768,000 customers on 24 January 2025. The last of them were reconnected on 11 February.

A battery tuned for tariffs is a poor fit for that week. A 20% reserve is 2.7 kWh, and a dull January day might add a few kWh from the roof. So winter needs its own reserve setting.

  • From October to March, hold a higher floor. 30–40% costs little, because you're refilling every night anyway.
  • When Met Éireann issues an orange or red wind warning for your county, set the reserve to 100% with grid charging on, and leave it there until the warning passes.

Elsewhere, Tesla's Storm Watch does the second part automatically. Tesla doesn't list Ireland among its Storm Watch markets, so here it's a job you do by hand.

Also check that you actually have backup. Not every Irish install is wired for it, and without the backup hardware the reserve number does nothing in a power cut.

One rule set for the Irish year

Here's the whole thing as rules. Adjust the times to your tariff.

  • November–February: grid charging on at the start of your cheap window, reserve to 100%. At the end of the window, reserve back to 30–40%.
  • March–April and September–October: same, but set the reserve to 50–60% so there's room for solar. When the window ends, drop it to 30% in March and October and 20% in April and September.
  • May–August: on a boost or EV tariff, keep the full night charge and export the solar. On a plain night rate, switch the night charge off.
  • Every day at 4:55pm: grid charging off and reserve back at its floor. The seasonal rules already drop the reserve when the cheap window ends, so this one is a safety net. It catches a manual change or a storm top-up you forgot to undo, so nothing pulls from the grid through the 5–7pm peak. The cheap-window rule turns grid charging back on each night.

That's about seven time-based rules with month filters: a start rule and an end rule for each season, plus the 4:55pm one. You can build them with Home Assistant and a weekend. Then Tesla changes something, your supplier moves the window, and you're debugging a script in January.

Grid Getter runs the same rules for you, and you never maintain the script. A Custom Schedule rule sets the mode, reserve or grid charging at a time you pick, on the months and days you pick. Time-based rules are checked every 60 seconds.

Some limits to know before you sign up:

  • The free plan includes live monitoring and one Custom Schedule rule, without grid-charging control. The rule set above needs a paid plan, which has unlimited automations.
  • In Ireland you subscribe through the iPhone or Android app, not the website.
  • Rate plan lookup isn't live outside the US yet, so you enter your own windows.
  • Rules run on the clock. They don't read half-hourly dynamic prices or Met Éireann warnings, so the storm top-up is still a tap from you.
  • Reserve can be set up to 80%, or to 100%. Tesla doesn't allow anything in between.

Start free and see what your battery does overnight before you change anything.

Tonight, find two numbers: the exact start and end of your cheapest window on your bill, and your Powerwall's charge rate during a grid charge in the Tesla app. Multiply the rate by the hours. If the answer is under 12 kWh, your battery isn't filling in the cheap window, and the first rule to fix is when charging starts.


Sources

Put your Powerwall on Irish tariff rules

Free to start. No credit card. Your utility's rate plan preconfigured and ready.

✓ Live Powerwall monitoring ✓ DemandGuard automation ✓ SRP & APS built in
Get Started Free →

Is your home battery doing what you bought it for?

Get a free report from your own battery data: a verdict on each of your goals, and your biggest demand peak of the past 12 months. Read-only, and deleted automatically.