Your biggest load just moved onto your meter
Leave the EV charger aside, and for years the biggest everyday loads in most Powerwall homes were the oven and the dryer. Put in a heat pump and that changes in one winter. A house that ran on 10 to 12 kWh a day in autumn can hit 30 kWh or more once the cold settles in, and the heat pump accounts for nearly all of the increase.
That's fine as long as the energy comes from somewhere cheap. Usually it doesn't. Most homes set their battery up once, in a mild month, picking a mode and a reserve and maybe a grid-charging setting, and then leave it. The heat pump changed the load, but the battery is still following the plan you made in spring.
A mode sits there all year. What a heat-pump winter needs is a rule that looks at the month, the time, and the state of charge, then acts on what it finds.
Why heat and peak hours overlap
A big share of a heat pump's work lands in the hours your rate plan charges the most for.
Outdoor temperature drops after sunset. That's when the house loses heat fastest, and the heat pump's efficiency (its COP) falls with the air temperature. If it's 8°C (46°F) at 2pm and 0°C (32°F) by 8pm, an air-source unit putting out 3.5 units of heat per unit of electricity in the afternoon might manage 2.5 in the evening. You're asking for more heat and paying more electricity for each unit of it.
People also come home. Lights, cooking, showers, and the thermostat climbing back from its daytime setback all land in the same evening stretch, and most time-of-use plans put their peak window right on top of it because the whole grid is doing the same thing.
And winter solar is weak. The days are short and the sun sits low. A system that fills your Powerwall by noon in summer might get it to 50 or 60% on a clear winter day, and barely at all when it's overcast. So the battery starts the evening less full on exactly the days you need it most.
Many plans also have a morning peak, and that's where the heat pump's recovery run lands after an overnight setback.
Pre-heat the house, pre-charge the battery
The fix is to move both kinds of storage into the cheap hours. Your battery holds electricity, and your house holds heat.
Pre-heat the building
Your walls, floors, furniture, and water all store heat. If you bump the setpoint 1.5 to 2°C (about 3°F) during the cheaper, warmer part of the afternoon, the heat pump runs at a better COP and the building carries some of that heat into the peak window. Then you let the setpoint drift down a degree during peak and the compressor runs less.
How well this works depends on the house. A well-insulated, heavy building can coast for hours. A drafty timber-frame one might give you 45 minutes. Try it for a week and watch the indoor temperature curve.
A heat pump water heater, or a tank heated by your space-heating heat pump, is even easier. Heat the tank midday or overnight and leave it alone during peak.
Pre-charge the battery
This half is about the Powerwall. If solar won't fill the battery before peak, you top it up from the grid in the cheap window, where your installation and supplier allow grid charging.
Here's one cold evening with real numbers. Say your peak window runs five hours:
- Base household load averages 0.8 kW, so 4 kWh
- The house loses about 5 kW of heat at 2°C outside. At a COP of 2.8, that's roughly 1.8 kW of electricity, or 9 kWh over five hours
- Total: 13 kWh in the peak window
One 13.5 kWh Powerwall with a 20% reserve has 10.8 kWh to give, but only if it starts full. If winter solar got it to 60% by the start of peak, it holds 8.1 kWh. Take off the 2.7 kWh reserve and you have 5.4 kWh available. That leaves 7.6 kWh to buy at peak rates.
Pre-charging can't cover all of that. A battery at 60% only has room for another 5.4 kWh before it's full, so topping it up off-peak shifts 5.4 kWh out of the peak window, and the other 2.2 kWh still comes from the grid at peak. That part is a capacity limit, and no charging schedule fixes it.
Now use 0.40 per kWh at peak and 0.12 off-peak. Read those as dollars, pounds, or euros, whatever your plan uses. Buying that 5.4 kWh at peak costs 2.16. Pre-charging it off-peak means buying about 6.0 kWh to allow for roughly 10% round-trip loss, which costs 0.72. That's about 1.44 saved per cold day, or around 43 across a winter month.
Your spread might be wider or narrower. The structure of the calculation stays the same.
Sizing reality: one Powerwall, big heat pump
Most Powerwall systems were sized for summer, when the goal was soaking up excess solar. Winter flips that. Capacity suddenly limits you, because there's more load and less free energy to fill the battery with.
That's the 2.2 kWh left over in the worked example. Even starting at 100%, one Powerwall with a 20% reserve covers 10.8 of the 13 kWh. On a colder night with a lower COP, the heat pump alone could use the whole battery. One battery can't carry a heat-pump home through a winter day. On a good day it can carry most of a peak window, so aim for that.
Power matters too. A Powerwall 2 puts out about 5 kW continuous. Run a heat pump compressor, a backup resistance element, and an oven together and you'll go over that, with the excess coming from the grid. A Powerwall 3 manages around 11 kW, which covers far more of that overlap.
Before you buy a second battery, work out how much of your peak-window shortfall is really "the battery started half empty." If that's most of it, the fix is a charging rule. A second Powerwall is a whole new install.
Rules that make the pair behave
One limit up front: Grid Getter doesn't control your heat pump or thermostat. Set the pre-heat schedule in the heat pump's own controller or your smart thermostat. Grid Getter runs the Powerwall side, so the battery is full and ready when the heat pump starts pulling.
Here's how that maps to rules you can set up today.
Pre-Peak Charge
This is the main winter rule. It reads the weather forecast and your recent solar output, and predicts whether the battery will reach your target by the time peak starts. If it won't, it grid-charges during off-peak to cover the gap. You choose the target percentage and a "battery full by" time. It re-checks every 15 or 30 minutes, so a sunny day after a grey forecast doesn't waste a grid charge. It doesn't have its own day or month settings. It takes its schedule from your Peak Time (or DemandGuard) rule, so you need one of those set up for it to know when peak starts. It's on the Adaptive plan.
Custom Schedule, limited to your cold months
Custom Schedule rules fire at a set time and can switch the operating mode, set the reserve, and turn grid charging on or off. Restrict them to the months your heat pump actually works hard. One example: during your cold months, at the start of your overnight cheap window, switch to Time-Based Control with grid charging enabled. Then switch back to Self-Powered before the morning peak. Time-based rules are checked every 60 seconds.
Turning grid charging on lets Tesla's optimizer charge from the grid. It doesn't make it do so. Whether it actually charges depends on the tariff you've entered in the Tesla app. If you need a top-up you can count on, use Pre-Peak Charge or Battery Protection, which charge to a target you set.
Your summer setup stays as it was. The winter rules only run in winter, and you don't have to remember to change anything over.
Battery Protection as a safety net
This one watches state of charge during a time window you choose. If the battery falls below a threshold, say 30% during the cheap afternoon hours on a dark day, it grid-charges back up to a target. On a paid plan it can also hold that level until the window ends. That's for the day when the morning recovery run drained more than the forecast expected.
Peak Time reserve
During the peak window you may want a lower reserve, so more of the battery goes to the heat pump instead of sitting idle. Peak Time sets the reserve for your peak hours and puts it back afterward. If your rate plan also bills on peak kW, DemandGuard watches the live draw and keeps compressor-plus-oven spikes off the grid.
On plans: Free covers one Custom Schedule rule (without grid-charging control) and one basic Battery Protection rule. Peak Time needs a paid plan, and Pre-Peak Charge is on Adaptive.
Set it up before the next cold snap
Grid Getter was built by a Powerwall owner who got tired of watching the meter. You could write all of this yourself against Tesla's API, and some people do. The catch is keeping it running: tokens expire, the API changes, and the tariff gets updated the week you're away. Grid Getter runs the rules, and you never maintain the script. Start free or get the app, then add your winter rules in one sitting.
Before you do, open the Tesla app on the next cold day and check two things. First, the battery's state of charge at the moment your peak window starts. Second, whether you pulled from the grid during that window. The app's energy totals are for the whole day, so scrub the power graph across your peak hours and look for grid draw. If the battery started below about 80% and you're importing at peak rates, that's what your current mode is costing you, and you can work out the monthly figure with the math above. If the battery started full and you still imported, the cause is the output limit (heat pump plus oven going over what the Powerwall can deliver), not charge timing.